User Instructions Cyrus 6 Power, 8 Power & X Power
5
GB
GB
OPERATION - 6 Power, 8 Power & X Power
Key to the front panel drawing (Fig.2)
1. Standby Switch
2. Standby Light
3. Mono Light (8 Power & X Power only)
Switching On
The mains power switch 1$ on the rear panel of the 6/8/X Power should be left
on for normal operation, except when left unattended for a long period when it
should be switched off or disconnected from the AC supply.
When power is applied, the STANDBY key a may be used for power control.
The Standby light b shows red when the 6/8/X Power is in Standby and green
when operational.
In addition to manual power control from the STANDBY key, the 6/8/X Power
also features a music sensing automatic power control which listens for the
presence of an input signal and will switch on if music begins to play. If the
6/8/X Power has been activated in this way it will reset to Standby five minutes
after the music has stopped.
Remote power control can also be enabled by connecting the MC-Bus sockets
c of the 6/8/X Power to a Cyrus system which includes a Preamplifier,
Integrated amplifier or Surround decoder. A number of 6/8/X Powers may be
connected in this way to provide remote standby control of all the system
power amplifiers.
Disabling the Music Sensor
In some installations a number of 6/8/X Power amplifiers may be driven from a
single preamplifier source to feed loudspeakers in several extension rooms. In
systems such as these it may be preferable to disable the Music Sensor to
prevent all amplifiers switching on when music commences.
The user can disable the Music Sensor by holding the front panel Standby key
whilst switching on the unit at the rear. The amplifier will now respond only to
the front panel standby button and MC-Bus commands. The Music Sensor will
remain disabled until power is next disconnected from the unit.
The Music Sensor may also be permanently disabled by returning the 6/8/X
Power to your retailer or the Cyrus factory for an internal adjustment.
NOTE:- If MC-Bus connections are made to the 6/8/X Power the music sensor
is disabled automatically.
FRONT PANEL INDICATORS – 8 Power & X Power
MONO Indicator
The MONO Indicator c will glow red if the rear panel STEREO/MONO switch
h is set for MONO Operation. This switch can be operated only when the 8/X
Power is in Standby. Operating it at any other time activates the fault indication
system.
TROUBLESHOOTING GUIDE
If your 6/8/X Power is not operating properly, disconnect the power and check
all connections using the notes in this manual. If problems persist, the
checklists below may help.
If you are in any doubt, consult your dealer.
No sound from either speaker
Preamplifier mute switch is on Deselect Mute
Loudspeakers are disconnected Check speaker connections
Fault indication on the front panel of
your 6/8/X Power
See ‘Fault Indication System’
No sound from one loudspeaker
Does your speaker have fuses? Check speaker, replace fuses
Speaker cables or interconnects
faulty
Check connections, cables - replace
if needed
Mono installations: Check connections are correct to
input and output of both amplifiers.
Poor quality sound in two channel stereo mode (8/X Power)
Selector switch incorrectly set to
mono
Set the switch to stereo
Poor quality sound in single channel mono mode (8/X Power)
Selector switch incorrectly set to
stereo
Set the switch to mono
Speakers plugs not connected to the
correct terminals
Check all speaker connections
carefully
FAULT INDICATION SYSTEM
The 6/8/X Power has a powerful protection system and fault indication system
designed to prevent damage to your hi-fi system and help you diagnose a
possible problem. If a fault persists, reset the amplifier via the rear panel mains
switch.
FAULT INDICATIONS
Standby light flashing Green / Yellow
This indicates overload in at least one
channel. If the problem is temporary
(e.g. excessive volume), normal
operation will resume after ten
seconds. If the fault indication
persists, there may be a problem with
the speakers or connections.
Switch off the power at the rear panel
and unplug the speaker cables. If the
fault indication clears when power is
re-applied, check the loudspeakers,
cables and plugs for loose strands of
wire causing a possible short circuit.
Standby light flashing Green
A fault has been reported from the
PSX-R (8/X Power)
Switch off the power to the 8/X
Power and the PSX-R Switch on
again. If the problem does not clear,
return both units to your Cyrus
distributor for checking.
The PSX-R is disconnected or
switched off. (8/X Power)
Check there is power to the PSX-R
and check the PSX-R connection to
the 8/X Power.
Standby light flashing Yellow / Red
The 6/8/X Power has over heated. Check the ventilation around the
6/8/X Power. Allow the unit to cool
down before re-applying power.
MONO light flashing (8/X Power)
The STEREO/MONO switch has
been changed whilst the amplifier is
operating.
Return the switch to its original
position.
If after taking remedial measures a fault condition remains, you should return
the 6/8/X Power to your Cyrus appointed dealer or an authorised Service
Centre.
Comentários a estes Manuais